13
Technical data
Power source RALLYMIG 161i
Mains voltage ±15% (50Hz-60Hz), V 1x230
Minimum generator size, kVA 6.5
Fuse, A 16
Mains current effective, A 13.0
Mains current max., A 22.9
Power (100%), kVA 2.4
Power max., kVA 4.4
Open circuit power, W 30
Efficiency 0.8
Power faktor 0.99
Current range, A 20-160
Duty cycle, 100% at 20°C, A 135
Duty cycle, 60% at 20°C, A 145
Duty cycle, 40% at 20°C, A 160
Duty cycle, 100% at 40°C, A/V 100/24.0
Duty cycle, 60% at 40°C, A/V 115/24.6
Duty cycle, max. at 40°C, A/%/V 160/25/26.4
Open circuit voltage, V 90
1)
Sphere of application
S/CE/CCC
2)
Protection class IP23S
Norm EN/IEC60974-1.
EN/IEC60974-5.
EN/IEC60974-10
Dimensions (HxWxL), mm 370x230x450
Weight, kg 13
1) S This machine meets the demand made for machines which are to operate in areas with increased hazard of electric chocks
2) Equipment marked IP23S is designed for indoor and outdoor applications
EC DECLARATION OF CONFORMITY
MIGATRONIC A/S
Aggersundvej 33
9690 Fjerritslev
Denmark
hereby declare that our machine as stated below
Type: RALLYMIG 161i
conforms to directives 2014/35/EU
2014/30/EU
2011/65/EU
European standards: EN/IEC60974-1
EN/IEC60974-5
EN/IEC60974-10 (Class A)
Issued in Fjerritslev 17.05.2017
Niels Jørn Jakobsen
CEO
0
10
20
30
40
50
60
70
80
90
0 40 80 120 160
I2 [A]
Static Characteristic
RallyMig 161i
MIG Load line