38
COMPONENTS
SW1 - Reset Switch
This restarts the program sequence in the same way as a power down at the main power switch.
SW2 - Dip Switch
This dip switch is used to setup the configuration of the 9700T module. Do not change unless instructed by
Miller Welding Automation.
Wire – Bit 4 Off, Bit 5 On
Reserved – Bits 1 & 3 Off
Rabbit Processor – Bit 4 On (20-101-1093), Bit 4 Off (20-101-1154)
R36 – Variable Resistor
This variable resistor is used to control the contrast of the display.
TEST POINTS
TP1 – 9700-10 5 Volt
Used to check the 5 Volts going to the 9700-10 board.
TP2 – 9700-10 Ground
When measuring the signals of this board, connect your isolated instrument ground lead here.
TP3 – Analog Input 1
Connect the red lead of your meter here to measure the analog signal from the tachometer. This value has
been scaled on the 9600-11R board.
TP4 - Analog Output 1
Connect the red lead of your meter here to measure the analog signal going to the motor controller.
TP5 – Analog Input 2
Connect the red lead of your meter here to measure the analog signal from the remote input. This value
has been scaled on the 9600-11R board.
TP6 - Analog Output 2
Connect the red lead of your meter here to measure the analog signal going to the spare output.
9600-11R Isolation Board- Located inside enclosure near output amphenol connectors.
CONNECTORS
J1 - Power Supply Connector