EMF DATA SHEET FOR INDUCTION HEATING POWER SOURCE
MILLER Electric Mfg. LLC, 1635 Spencer Street, Appleton, WI 54914 U.S.A. is voluntarily providing the following
information to assist European employers in carrying out their
assessments to show compliance with Directive
2013/35/EU on the minimum health and safety requirements regarding the exposure of workers to the risks arising
from physical agents (electromagnetic fields).
Product/Apparatus Identification
Product Stock Number
ARCREACH HEATER 301390
Compliance Information Summary
Applicable regulation Directive 2014/35/EU
Reference limits Directive 2013/35/EU, Recommendation 1999/519/EC
Applicable standards None
Intended use
☒
for occupational use
☐
for use by laymen
Sensory effects need to be considered for workplace assessment
☐
YES
☒
NO
Non−thermal health effects need to be considered for workplace assessment
☒
YES
☐
NO
Thermal health effects need to be considered for workplace assessment
☐
YES
☒
NO
☒
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
☐ Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
☐
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
EMF Data for Non-thermal Health Effects
Minimum approach distances to pipe/coil where EMF exposure limi
t values are not exceeded (ELV Exposure Index v 1)
Output Current
Body Part
Head Trunk Hand Thigh
200 A 8 cm 9 cm 3 cm 8 cm
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%) 23 cm
Distance where all general public
ELV Exposure Indices fall below 1.00 (100%) 56 cm
For applications when more than one FieldPro Heater is used on a common work piece, please contact Miller
Electric Mfg. LLC directly for minimum approach distances
.
Assessment performed by: Divya Natarajan Date performed: 2017−11−01