Do you have a question about the Millipore Milli-Q Advantage A10 and is the answer not in the manual?
Model | Milli-Q Advantage A10 |
---|---|
Resistivity | 18.2 MΩ·cm at 25 °C |
TOC | < 5 ppb |
Pyrogens (Endotoxins) | < 0.001 EU/mL |
Power Supply | 100-240 V, 50/60 Hz |
Type of Water Produced | Type I ultrapure water |
Flow Rate | Up to 1.5 L/min |
Feed Water Requirements | Potable water or pretreated water |
Purification Technology | Reverse osmosis, ion exchange |
Display | Touchscreen |
Storage Capacity | 10 L |
General statement on safe operation and maintenance of the Milli-Q System.
Explanation of hazard, attention, UV radiation, danger, and ground symbols used in the manual.
Explains the purpose, scope, and terminology used in the user manual.
Provides contact information and manufacturing site details for Millipore.
Describes the Milli-Q System Cabinet and its input/output connections.
Details the performance specifications for Milli-Q water, including flowrates, resistivity, TOC, etc.
Illustrates the water flow path through the Milli-Q System with component descriptions.
Presents dimensional data for the Milli-Q Cabinet and Q-POD Dispenser.
Lists necessary consumables, space, weight, and electrical requirements for installation.
Step-by-step instructions for assembling the Q-POD Dispenser unit.
Details how to connect the RC-Link tubing to the Q-POD Dispenser Base.
Instructions for connecting the feedwater tubing from a reservoir or loop.
Instructions on where to store the quick reference guide within the system cabinet.
Step-by-step guide to power on the Milli-Q System for the first time.
Detailed steps for installing the Q-Gard Pack into the Milli-Q System Cabinet.
Instructions for inserting the Quantum Cartridge into the Milli-Q System Cabinet.
Procedures for rinsing the system, purging air, and hydrating purification media.
Refers to Section 5-7 for instructions on cleaning the A10 TOC Monitor.
Guides on installing a POD Pak on the Q-POD Dispenser and registering its installation.
Step-by-step instructions to access the password-protected Manager Menu.
Procedure for changing the system's display language.
Instructions on how to configure the system's date and time settings.
Guide to calibrating the water flowrate using a graduated cylinder.
Explains how to adjust set points for alerts and alarms.
Instructions for changing measurement units for water quality and reservoir levels.
Explains how to adjust temperature compensation modes for resistivity and conductivity measurements.
Details how to adjust the automatic water recirculation time per hour.
Instructions for adjusting the timer that automatically stops dispensing water.
Procedure for configuring buzzer settings for alarms and alerts.
Guide to changing the system login ID and password.
How to set user parameters for reports, such as company name and address.
Procedure for registering the lifetime of UV 185 nm and A10 lamps during installation.
Description of the main display interface and the function of each keypad button.
Visual representation of the Milli-Q system's software structure and navigation.
Explains the differences and usage of STANDBY and READY modes.
Instructions on how to dispense water, adjust height, and use different flow rates.
Steps to view and print the current water quality parameters.
Details the icons and symbols on the Q-POD display and their meanings.
Procedure to print the system's historical data and events.
How to access and view system operation status, alerts, and measures.
Check the status and expected replacement dates for consumables like Q-Gard Pack and Quantum Cartridge.
Provides contact information for Millipore service and support.
Access service history, contract expiry, and calibration dates.
Access flow schematic, version, and system serial number information.
Lists maintenance items, when they are needed, and how to perform them.
Detailed steps for removing and installing a new Q-Gard Pack.
Procedure for removing and installing a new Quantum Cartridge.
Instructions for replacing a POD Pak due to flowrate decrease or alert messages.
Information on when and how to replace the UV 185 nm Lamp.
Guidance on when and how to replace the A10 Lamp, recommending service engineer.
Steps for cleaning the A10 TOC Monitor when needed.
Procedure for cleaning the inlet strainer to ensure proper feedwater flow.
Summarizes different types of alert and alarm messages and their significance.
Steps to view and clear alert messages from the system displays.
Procedure to view and cancel alarm messages displayed by the system.
Lists alert messages, their meanings, and recommended actions.
Provides a list of alarm messages, their causes, and troubleshooting steps.
Lists consumable items with their catalogue numbers and comments.
Lists accessories for the Milli-Q system with their corresponding catalogue numbers.
Provides catalogue numbers for the Milli-Q Advantage A10 System and its Q-POD Dispenser.