9
Changing vacuum control unit parameter
It is necessary to change the parameter of the vacuum control unit.
1. Remove the screws (for four positions)
and the control unit cover.
2. Disable the data protection function of the inverter.
(1) Enter into the function code data screen of the function code “F00”.
(2) By pressing [STOP] + [] or [STOP] + [], change the function code data of F00 from
“1” to “0”.
Menu
Function code
Operation mode
Function code data
Operation procedures
Operation mode
Program mode
[PROG/ RESET] key
[FUNC/ DATA] key
Display example 1
“1.F--” “1.E--” “1.C--” ---
(Display is changed with []/[])
Display example 2
“F00” “F01” --- “E01” “E02” --- “C01” “C02” ---
(Display is changed with []/[])
Display example 3
“1” (for F01)
(Display is changed with []/[])
With the data
fixed, go to the
function code.
Without the data
fixed, go to the
function code.