MAINTENANCE MANUAL > Workflow > Electrical Parts > Replacement of the Power Supply PBA600F-36-G
Model
SWJ-320S
Issued
2012.07.19
Revised
2013.08.28
F/W ver
Remark
1.1
Rev.
3.3.2 Replacement of the Power Supply PBA600F-36-G
OLD (SWJ-320S2: ~M031E120 / SWJ-320S4: ~M131E524)
List of replacement procedures
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pres-
sure part of the DC power supply unit. Take care to avoid contact with it.
Item Work operation Description Ref.
Power OFF
1.
Power OFF
Power cable removing from main
body
Turing the main power OFF, and then removing the power
cable from the main body.
---
DC Power
Supply
2.
DC Power Supply (DC37V) replace-
ment
6.4.2
Adjustment
3.
Power ON Connecting the power cable to the main body, and starting
the machine.
---
4.
Power voltage adjustment Monitoring the power with a tester and adjusting the volume
of DC power supply(DC37V).
4.2.23
PBA600F-36-G