© 2013 MIMAKI ENGINEERING CO.,LTD. 4.2.5 P.2
4.2.5 [HEAD ADJUST] SLANT ADJUST
R.1.0
1
2
3
4
5
6
7
8
Head slant check procedure
1. Select [#ADJUST] -> [HEAD ADJUST] -> [SLANT ADJUST]
from the operation menu.
2. Select HEADline1.
3. Press the [ENTER] key to print the pattern.
[ENTER]: starts printing pattern.
[FUNCTION]: Cap OFF
[CLEANING]: Cleaning is curried out.
[]/[]/[]/[]:enters into the jog mode (moves the
origin of the pattern)
Slant adjustment procedure
1. Confirm whether quantity of biggest gap by each scan is
settled 30 μm. If there is a head whose gap is out of the
standard, carry out the following adjustment.
<LOCAL>
width:1000mm
FUNCTION
#ADJUST [ENT]
#ADJUST
HEAD ADJUST [ENT]
[FUNCTION]
#HEAD ADJUST
SLANT ADJUST [ENT]
#SLANT ADJUST
PRINT START [ENT]
Do not perform this adjustment with the carriage
located on the Station Assy (cap). Make sure to cap
off.
MAINTENANCE MANUAL > Adjustment > Adjustment Items > [HEAD ADJUST] SLANT ADJUST
Model
SWJ-320S
Issued
2013.03.08
Revised F/W ver
2.20
Remark