© 2013 MIMAKI ENGINEERING CO.,LTD. 4.2.13 P.2
4.2.13 HEAD WASH
R.1.2
1
2
3
4
5
6
7
8
6. Move the Carriage to left maintenance position with press
[ENTER] key.
7. Insert the air purge jig into the ink port, and purge the washing
liquid.
8. Manually perform wiping.
9. Move the Carriage to the capping position with press [ENTER]
key.
10. Remove the wash bottle, and press the [ENTER] key.
11. .Repeat above procedure steps from 5. to 8.
12. Move the Carriage to the capping position with press [ENTER]
key.
13. Clean the wiper and cap.
Press [ENTER] key after cleaning is completed, and then finish
the procedure.
Purge button
INKPORTWASHING
START [ENT]
Carriage moves to Left
maintenance position.
Set so that the tips of the air purge jig come into
contact with the bottom of the discharge tray.
Counter flow of the washing liquid and inflow of
the air may be occurred.
Purge the air and then discharge the washing liquid
from the tip of the jig by pressing the purge button,
and then end after it is completed.
INKPORTWASHING
COMPLETED [ENT]
REMOVEWASHBOTTLE
COMPLETED [ENT]
Carriage moves to Capping
position.
WASHING
PLEASEWAIT
INKPORTDISCHARGE
COMPLETED [ENT]
WIPER&CAPCLEANING
COMPLETED [ENT]
Carriage moves to Capping
position.
MAINTENANCE MANUAL > Adjustment > Adjustment Items > HEAD WASH
Model
SWJ-320S
Issued
2012.07.19
Revised
2013.03.08
F/W ver
1.0
Remark