4.2.16 DEFAULT SET
Function
Sets the selected parameters to the initial values.
Procedure
1. Select [DEFAULT SET] from the operation menu.
2. Select items to be initialized.
3. Initialize the selected parameter.
No. Item Operation Remarks
1 SETUP PARAMETER 1. Initialize the user operation setting value.
2. Sets user No. to 1.
3. Initialize the language to be used.
4. Initialize the user dot position
compensation value.
5. Sets to maintenance close.
Always selectable
2 MAINTENANCEparameter Initialize the parameter in question.
3 CUSTOMIZE PARAMETER Initialize the parameter in question.
4 RUNNING PARAMETER Initialize the parameter in question.
5 EXCHANGE PARAMETER Initialize the parameter in question.
6 INK-SYSTEM PARAMETER Initialize the parameter in question.
<LOCAL. 1> [#01]
FUNCTION
#ADJUST <ENT>
#ADJUST
DEFAULT SET <ent>
[FUNCTION]
#DEFAULT SET
SETUP PARAMETER <ent>
MAINTE PARAM. <ent>
CUSTOM PARAM. <ent>
:
[] / []: Switches parameter item
display.
[ENTER]: Finalizes (to initialization
screen)
SETUP PARAMETER
INITIALIZE OK? :ent
[ENTER]: Executes the initialization
MAINTENANCE MANUAL > Adjustment Items > Adjustment Function > DEFAULT SET
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver.
1.20
Remark
1.0