5.1.20 SKEW CHECK
Function
Skewing of media is checked.
When media is not detected, an OPERATION ERROR (ERROR30) is displayed.
Feed distance is designated to execute feeding.
Feed distance: 1–500 m (unit: 1 m)
During the feeding, remaining of feed distance is displayed with unit of 10 mm.
[END]: Aborts feeding, [ENTER]: Restarts feeding.
Cut jig function
After the Skew check starts (feed distance is not designated), the following operation starts the cut jig function.
[REMOTE] -> [FUNCTION]
The cut jig function repeats media cut feed in feed distance and number of cut times designated.
Number of cut times is displayed in count down during cut.
Feed distance : 10–10000 mm (unit: 10 mm, Default 500 mm)
Number of cut times : 1–1000 count (unit: 1 count, Default 25 count)