© 2011 MIMAKI ENGINEERING CO.,LTD. 5.2.7 P.2
5.2.7 Checking Conduction of HDC FFC Data Line
1
2
3
4
5
6
7
8
Procedure
1. Check the conduction of HDC FFC data line as the figure on the
left.
2. See the figure on the left for the IC pin number.
The mark side is the start of the number.
M Y K C
C K Y M
M Lc Y M
C K C Lm
M Y Lc W
C K Lm W
4-color ink set 6-color ink set 6-color + white ink set
A line C line E line G line
B line D line F line H line
A line C line E line G line
B line D line F line H line
A line C line E line G line
B line D line F line H line
MainPCB
(Head1side)
HDCPCB
(Head2side)
SliderPCB
Tester
1.6Ω
HDC FFC
The resistance undergoes a little bit change with the
probe location or temperature.
R.1.1
MAINTENANCE MANUAL > Test Items > Other Test > Checking Conduction of HDC FFC Data Line
Model
TS34-1800A
Issued
2011.10.17
Revised F/W ver
1.20
Remark
1.0