4.2.9 P.2
4.2.9 CAPPING
1
2
3
4
5
6
7
8
5. Position the screw right in front of the steeply-inclined slot.
[]/[]: Shifts the cap.
[ENTER]: Finalizes (To Next)
6. Adjust the wiper waiting position.
After the wiper moves, press the [FUNCTION] key to check the
adjustment value.
[]/[]: Horizontally shifts the wiper.
[ENTER]: Finalizes
7. Make adjustment so that each center of the wiper and the head
coincides.
After the wiper moves, press the [FUNCTION] key to check the
adjustment value.
Adjust the 2nd head in the same way.
[]/[]: Horizontally shifts the wiper.
[ENTER]: Finalizes
[END]: Completes
#CAPPING
FlushingPOS2= 0.0mm
If the screw is positioned in the steeply-inclined
groove, impact noise will be generated at the time of
refreshing.
The screw is positioned right in
front of the steeply-inclined slot.
OK
No Good
The screw is positioned in the
steeply-inclined slot.
#CAPPING
Wiper Home = 0
Adjust it to the position where the wiper driving link
may not hit the wiper base 34 (the position where no
noise sounds).
#CAPPING
WiperPOS(1) = 0
#CAPPING
WiperPOS(2) = 0