EasyManua.ls Logo

Mindeo CS2190 - Code 93

Mindeo CS2190
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
63
3-21 Code 93
Read:
Format
Data digits (variable)
2 check digits (optional)
Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data
digits.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
3-13 Code 39
.
Code ID setting: Refer to Code ID setting of
3-11 UPC-A
.
Insertion group selection: Refer to Insertion group selection of
3-11 UPC-A
.

Other manuals for Mindeo CS2190

Related product manuals