17
7. Specifications
7−1. Specifications
Power supply voltage to rotor AC20.0 Vrms Square wave 11.2 kHz±0.2 kHz
Applicable transducer Optical transformer method torque transducer
Input range 5 kHz to 15 kHz
Output ±10 V
Output load resistance Load resistance 2 kΩ or more
Load of output capacitance 0.1 μF or less
Zero adjustment range ±15 %R.O.
Non−linearity 0.01 %F.S.
Temperature coefficient
Zero point ±0.025 %R.O./10 ℃
Sensitivity ±0.025 %R.O./10 ℃
CHECK Approx.80 %R.O Accuracy ±0.03 %
Frequency response range DC to 1 kHz (Filter:W/B)
(Changeable to 1 Hz, 10 Hz, 30 Hz, 50 Hz, 100 Hz, 300 Hz, 500 Hz or 1 kHz)
However, 10 Hz to 1 kHz:+1 dB, −3dB±1 dB, 1 Hz:+1 dB, −3dB±3dB
Display section
Display of output voltage 0 to ±10.000 digital display (Green LED)
Sampling Approx. 4 times/s
Remote function CHECK
ALARM function ALARM output
7−2. General specifications
Operating temperature/humidity range
0 ℃ to 40 ℃ 85 %RH or less (Non condensing.)
Power supply
Power supply voltage AC85 V to AC132 V
Power supply frequency 50/60 Hz
Power consumption Approx. 100 VA (at AC100 V)
Insulation resistance Between power line and case DC500 V, 100 MΩ or more
Between power line and case AC1 500 V, 1 min period
Outline dimension(W×H×D) 42 mm×176 mm×284.4 mm (Excludes protruding parts.)
Weight Approx.2.5 kg
7−3. Standard specifications at the shipment
SPAN 10 V output at rated output from torque transducer
Frequency response range 1 kHz
7−4. Accessories
Instruction manual 1 piece
Fuze(5 A) 1 piece
Output cable(2 m) 1 piece
Dust filter 10 pieces