11
5
Commands list(4 stations ,2 stations )
When the command order is executed by using the general command request (request 2), the
value set in command No. and the general data area is indicated as follows;
Writing the set value and operation request (Writing/Reading out selection=Writing [OFF])
Setting value or command request
Command No.
(RWw000E)
General data area
(RWw000C〜RWw000D)
S0 10 −99 999〜99 999
S1 11 −99 999〜99 999
S2 12 −99 999〜99 999
Tare weight cancellation ON(A/Z ON) 14
Tare weight cancellation OFF(A/Z OFF)
15
Zero set ON(ZERO)
0
16
Reset of sequence error 36
Reading out the setting value(Selection of writing/Reading out=Reading out[ON])
Setting value or Command request
Command No.
(RWw000E)
General data area
(RWw000C〜RWw000D)
S0 10 −99 999〜99 999
S1 11 −99 999〜99 999
S2 12 −99 999〜99 999
Numeric representation of a remote register is as shown in the table
below as a rule. However, the negative numeric expression is different
according to setting F−87. Please refer to the paragraph 4−1.
Decimal
32 bits data
number
16
ts
at
Upper position Lower position
0 0000H 0000H 0000H
1 0001H 0000H 0001H
10 000AH 0000H 000AH