7. SPECIFICATIONS
7.1 Safety & Compliances
Maximum voltage between
any terminal and earth
ground:................................. 1000 V AC/DC
Compliances: ....................... Complies with CSA C22.2 No 1010.1-
92, ANSI/ISA-S82, 01-94 to 1000 V
Overvoltage Category lll.
Certifications: ....................... UL & cUL standard UL 3111-1 Listed
CE marking certificated
Surge Protection: ................. 8 kV peak per IEC 1010.1-92
Fuse Protection for
mA or µA inputs: .................. 1000 V / 440 mA lR 10 kA Fast fuse
Fuse Protection for
A input: ................................ 1000 V / 11 A lR 10 kA Fast fuse
7.2 Physical Specifications
Display (LCD):...................... Digital – 50000 count primary display,
5000 count secondary display ;
updates 4 / sec. nominal
............................................ Analog – 25 segments, updates 40 /
sec.
Operating Temperature: ........ 0°C to 50°C
Storage Temperature: ...........–20°C to 60°C
Temperature Coefficient: ....... nominal 0.15 x (specified accuracy) /
°C @(0°C to 18°C or 28°C to 50°C),
............................................ or otherwise specified
Relative Humidity: ................ 0 % to 80 % @ (0°C to 35°C) 0 % to
70 % @ (35°C to 50°C)
Altitude: ............................... Operating – up to 2000m
............................................ Storage – 10000m