FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 DIS/REASSEMBLY, ADJUSTMENT
98.04.13
D-67
5. Press the Clear Key to clear the current setting
value.
6. With the old setting value used as reference, enter
the new setting value using the appropriate 10-
keys.
NOTE
If the erase width on the copy is less than 0.5 mm,
increase the setting value.
If the erase width on the copy exceeds 6.5 mm,
decrease the setting value.
1139D047CA
7. Press the Start Key to validate the setting.
8. Press the Panel Reset Key twice (or turn OFF the
Power Switch) to return the copier back to the nor-
mal mode.
9. Make two single copies and check for leading edge
erase width on the second copy. (If it does not
meet the requirement, perform steps 3 through 9
again.)
1139D019CA