Deployment Guidelines
1. Determine which traffic pole you will use to mount the SmartView 360. This is
typically the traffic pole nearest your traffic cabinet, but could be a different
traffic pole to meet these requirements:
It must be the traffic pole nearest the intersection.
It must be a hollow traffic pole or mast arm with access to run cabling
inside the pole. If you must mount SmartView 360 on a solid traffic pole, a
weatherproof junction box is required.
The line of sight from the camera must not be obstructed by signal heads,
mast arms, signs, trees, or other objects.
2. Determine where on the traffic pole you will install the SmartView 360, including
whether you will install it on a mast arm. The minimum recommended
installation height is 9.14 m (30 ft). You must supply a pole extender if the
planned pole is not tall enough.
3. Determine the size of your intersection by measuring from the base of the traffic
pole where the camera will be installed to the most distant location where you
want to detect objects.
In Google satellite view, you can do this by right-clicking at the base of the
pole where you want to install SmartView 360, clicking Measure Distance,
and then clicking the most distant location where you want to detect
objects. Make sure that you measure to the back the detection zone, not
to the corner of the intersection. As you consider different camera
locations, you can drag the two points around to update the distance.
For example, in this intersection the most distant detection zone is
displayed at the top of the image.
6.11.19
8