16
TAB 6.6 A
TAB. 6.7 A
6.5 LUBRICATION
Use ITW AMP Code Number T064 or equivalent oil
Furthermore, we recommend you lubricate the driver blade every 200 working hours.
Unsuitable lubricants may cause valve seal problems, (seals may become too large) and consequent Valve
jamming could occur.
6.6 ORDINARY MAINTENANCE
The following operations must be executed at the times indicated below. Not observing the following instructions exonerate
the Producer from any responsibility regarding the warranty.
The operations described here below, even if simple, must be executed by qualified personnel.
The scheduled ordinary maintenance includes overhauls, checks and interventions that will help prevent stops and breakdowns.
Lubrication state of the machine
Wear and tear parts state
MAINTENANCE
V-nail driver blade
Movable parts lubrication
V-nails clawheads
“L” shaped supports (V-nails guide)
DESCRIPTION
Replacement every 1.000.000 V-nails shot
Lubricate the driver blade every 200
working hours
Replacement every 5.000.000 V-nails shot
Replacement every 5.000.000 V-nails shot
MACHINE STATE
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
Isolation for maintenance
6.7 EXTRAORDINARY MAINTENANCE
Listed below are the operations that need the intervention of ITW/AMP or your local distributor’s Technical Assistance (see the
paragraph 1.2).
The extraordinary maintenance includes interventions to be peroformed in exceptional cases:
Breakage
Revisions
MAINTENANCE
Valves and Reducers
Frontal and vertical clamping
gaskets
DESCRIPTION
Suggested replacement every 6/8 million
of V-nails shot
Replacement in case of leak of air
MACHINE STATE
Isolation for maintenance
Isolation for maintenance