EasyManua.ls Logo

Mitsubishi Electric A800 User Manual

Mitsubishi Electric A800
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INVERTER
INVERTER A800
FR-A802-P INSTRUCTION MANUAL (HARDWARE)
A
INTRODUCTION
1
INSTALLATION AND WIRING
2
PRECAUTIONS FOR USE OF
THE INVERTER
3
PROTECTIVE FUNCTIONS
4
PRECAUTIONS FOR
MAINTENANCE AND
INSPECTION
5
SPECIFICATIONS
6
IB(NA)-0600651ENG-A(1611)MEE Printed in Japan Specifications subject to change without notice.
A800
FR-A802-P
(SEPARATED CONVERTER TYPE FOR PARALLEL OPERATION)
INSTRUCTION MANUAL (HARDWARE)
FR-A842-09620(400K) to 12120(500K)-P
High functionality and high performance
HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Table of Contents

Other manuals for Mitsubishi Electric A800

Questions and Answers:

Mitsubishi Electric A800 Specifications

General IconGeneral
SeriesA800
TypeInverter
Overload Capacity150% for 60 seconds
Operating Temperature-10°C to +50°C
Output Voltage0-Input Voltage
Power Rating0.4 kW to 560 kW
Control MethodV/f control, vector control
Braking UnitOptional
Communication ProtocolsModbus, CC-Link, Profibus
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Ground fault
Storage Temperature-20°C to +60°C
Humidity95% RH or less (non-condensing)
Input Voltage3-phase 200V to 240V, 380V to 480V
Output Frequency0.1-400 Hz
Frequency Range0.1-400 Hz

Summary

INTRODUCTION

Product checking and accessories

Check the rating plate and capacity plate of the inverter to ensure the model agrees with the order and the product is intact.

Inverter component names

Details the component names and their functions with reference pages for the FR-A802 inverter.

About the related manuals

Lists the manuals related to the FR-A802 inverter and their manual numbers.

INSTALLATION AND WIRING

Peripheral devices

Covers required peripheral devices for inverter and converter units, including selection guides.

Removal and reinstallation of the operation panel or the front covers

Provides instructions on how to remove and reinstall the operation panel and front covers.

Installation of the inverter and enclosure design

Details inverter installation environment, temperature, humidity, and enclosure design considerations.

Terminal connection diagrams

Illustrates terminal connection diagrams for FM type and CA type inverters, including parallel operation.

Main circuit terminals

Describes the main circuit terminals of the inverter and converter unit, including connection details.

Control circuit

Explains the control circuit terminals, input signals, output signals, and logic configurations.

Communication connectors and terminals

Covers RS-485 terminal blocks, PU connectors, and USB connectors for communication.

Connection of motor with encoder (Vector control)

Details wiring for vector control using motors with encoders, including appearance and terminals.

Parameter settings for a motor with encoder

Explains parameters for encoder setup and motor settings for vector control.

PRECAUTIONS FOR USE OF THE INVERTER

Electro-magnetic interference (EMI) and leakage currents

Addresses EMI and leakage currents, providing countermeasures and selection criteria for circuit breakers.

Power supply harmonics

Discusses power supply harmonics generated by the inverter and related suppression guidelines.

Power-OFF and magnetic contactor (MC)

Covers the use of magnetic contactors on the input and output sides for power control.

Countermeasures against deterioration of the 400 V class motor insulation

Recommends using insulation-enhanced motors to prevent insulation deterioration from surge voltages.

Checklist before starting operation

Provides a checklist of points to recheck before starting operation for product longevity and safety.

Failsafe system which uses the inverter

Explains interlock methods using inverter status signals and backup methods outside the inverter.

PROTECTIVE FUNCTIONS

Inverter fault and alarm indications

Details how faults and alarms are indicated on the operation panel and the inverter's status.

Reset method for the protective functions

Describes the procedures for resetting protective functions, including panel keys and reset signals.

Check and clear of the faults history

Explains how to check and clear the recorded fault history displayed on the operation panel.

List of fault displays

Provides a comprehensive list of fault displays, indicating their availability for master and slave stations.

PRECAUTIONS FOR MAINTENANCE AND INSPECTION

Inspection item

Covers daily and periodic inspection items, including precautions for safe maintenance.

Measurement of main circuit voltages, currents and powers

Details methods and instruments for measuring main circuit voltages, currents, and powers.

SPECIFICATIONS

Inverter rating

Presents the rated specifications of the inverter, including capacity, current, and voltage.

Common specifications

Outlines common specifications for the inverter, covering control, operation, and protective functions.

Outline dimension drawings

Provides outline dimension drawings for the inverter and the operation panel for installation planning.

APPENDIX

Instructions for compliance with the EU Directives

Explains compliance with EU Directives, including EMC and Low Voltage Directives, and CE marking.

Instructions for UL and cUL

Provides instructions for UL and cUL compliance, including wiring protection and motor overload protection.

Instructions for EAC

Details instructions for EAC marking compliance within the Eurasian Customs Union area.

Restricted Use of Hazardous Substances in Electronic and Electrical Products

Lists restricted hazardous substances in electronic and electrical products according to Chinese regulations.

Related product manuals