10Extended Function Relevant Error List
10-118
10 Extended Function Relevant Error List
(1) Error occurred when MELFA-BASIC IV is selected while shared memory extended function is valid
(2) Error occurred when the parameter ALWENA is set to one (enabled) while the sequencer direct perfor-
mance is valid
(3) Error occurred when MELFA-BASIC IV is selected while the sequencer direct performance is valid
Error No Error Cause and Measure
L3994 Error message Shared memory extended function unavailable (MB4)
Cause Shared memory extended function is unavailable in MELFA-BASIC IV.
The parameter RLNG=1 (MELFA-BASIC IV) is selected while shared memory extended function
is valid. Make sure to set the parameter RLNG to 2 (MELFA-BASIC V).
Measure Set the parameter RLNG to 2 (MELFA-BASIC V).
Error No Error Cause and Measure
L3995 Error message Unavailable together with the function (sequencer direct, ALWENA)
Cause Unavailable together with the function (sequencer direct, ALWENA)
The parameter ALWENA is set to one (enabled) while the sequencer direct performance function
is valid. During performing sequencer direct, X** commands are unavailable in the always run-
ning program. Make sure to set the parameter ALWENA to zero (disabled).
Measure Set the parameter ALWENA to zero (disabled).
Error No Error Cause and Measure
L3996 Error message Sequencer direct function unavailable (MB4)
Cause Sequencer direct function is unavailable in MELFA-BASIC IV.
The parameter RLNG=1 (MELFA-BASIC IV) is selected while the sequencer direct perfor-
mance function is valid. Make sure to set the parameter RLNG to 2 (MELFA-BASIC V).
Measure Set the parameter RLNG to 2 (MELFA-BASIC V).