8. Setup
8 - 18
No. Abbrev. Parameter name Explanation
Setting range
(Unit)
F EDCBA98765 4 3 2 10
1 rtyp emgx 0
bit
Meaning when "0" is set Meaning when "1" is set
0
1
2
3
4
Set the external emergency stop function. (Setting is prohibited for
values with no description.)
5 Setting Explanation
6
emg
x
0 External emergency stop invalid
7 4 External emergency stop valid
8 Set the regenerative resistor type.
9 Setting Explanation
SV036 PTYP* Regenerative A
rtyp
0 to 1 Setting prohibited
resistor type B 2 GZG200W26OHMJ
3 GZG300W20OHMJ
4 MR-RB32 or GZG200W120OHMJ 3 units connected in parallel
5 MR-RB30 or GZG200W39OHMJ 3 units connected in parallel
6 MR-RB50 or GZG300W39OHMJ 3 units connected in parallel
7 MR-RB31 or GZG200W20OHMJ 3 units connected in parallel
8 MR-RB51 or GZG300W20OHMJ 3 units connected in parallel
9 MR-RB65 or GRZG400-2OHMJ 4 units connected in serial
A GZG80W26OHMJ
B GZG400W13OHMJ
C GZG400W8OHMJ
D to F Setting prohibited
C Always set 1 (0001).
D
E
amp
F
(Note) Set to "0" for bits with no particular description.
Parameters with an asterisk * in the abbreviation, such as PC1*, are validated with the NC power is turned ON again.