Appendix 4. EMC Installation Guidelines
A4 - 12
MX13 Series 3-phase high attenuation noise filter for 200V
Features
Perfect for mounting inside control panel:
Easy mounting and maintenance work:
Terminals are centrally located on the
front
Complaint with NC servo and AC servo
noise:
High attenuation of 40dB at 150KHz
Safety Standards:
UL1283, CSA22.2 No.8, EN133200
Patent and design registration pending
Specifications
Type
Item
MX13030 MX13050 MX13100 MX13150
1 Rated voltage (AC)
3-phase 250VAC (50/60Hz)
2 Rated current (AC)
30A 50A 100A 150A
3
Test voltage (AC for one minute across
terminal and case)
2500VAC (100mA) at 25°C, 70% RH
4
Insulation resistance (500VDC across
terminal and case)
100M min. at 25°C, 70% RH
5 Leakage current (250V, 60Hz)
3.5 mA max. 8 mA max.
6 DC resistance
30 m max. 11 m max. 5.5 m max. 3.5 m max.
7 Temperature rise
30°C max
8 Working ambient temperature
–25°C to +85°C
9 Working ambient humidity
30% to 95% RH (non condensing)
10 Storage ambient temperature
–40°C to +85°C
11 Storage ambient humidity
10% to 95% RH (non condensing)
12 Weight (typ)
2.8kg 3.9kg 11.5kg 16kg
(Note) This is the value at Ta50°C.
Refer to the following output derating for Ta>50°C.
Contact: Densei-lambda Co., Ltd. Telephone: 03-3447-4411 (+81-3-3447-4411)