7 Applied Instructions
7.2 Move and Compare
174
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
7.2.10 BIN
Outline
This instruction converts binary-coded decimal (BCD) data into binary (BIN) data.
Use this instruction to convert a binary-coded decimal (BCD) value such as a value set by a digital switch into
binary (BIN) data and to receive the converted binary data so that the data can be handled in operations in
PLCs.
1. Format and operation, execution form
2. Set data
3. Applicable devices
S: Refer to "Cautions".
FX3U(C) FX3G FX2N(C) FX1N(C) FX1S FXU/FX2C FX0N FX0(S)
Instruction
name
Operation
Execution
form
Expression in each language
Structured ladder ST
BIN 16 bits Continuous BIN(EN,s,d);
BINP 16 bits Pulse BINP(EN,s,d);
DBIN 32 bits Continuous DBIN(EN,s,d);
DBINP 32 bits Pulse DBINP(EN,s,d);
Variable Description
Data type
16-bit
operation
32-bit
operation
Input
variable
EN Execution condition Bit
Word device storing the conversion source
(binary-coded decimal) data
ANY16 ANY32
Output
variable
ENO Execution state Bit
Word device of the conversion destination (binary) ANY16 ANY32
Operand
type
Bit Devices Word Devices Others
System User Digit Specification
System
User
Special
Unit
Index
Constant
Real
Number
Character
String
Pointer
XYMTCS
D.b
KnX KnY KnM KnS T C D R
U\G
V Z Modifier K H E
""
P
zzzzzzz
S1 S2
zz z
zzzzzz
S1 S2
zz z
BIN
EN
s
ENO
d
BINP
EN
s
ENO
d
DBIN
EN
s
ENO
d
DBINP
EN
s
ENO
d