7.23.6 BINDA
Outline
This instruction converts binary data into decimal ASCII codes (30H to 39H).
1. Format and operation, execution form
2. Set data
3. Applicable devices
FX3U(C) FX3G FX2N(C) FX1N(C) FX1S FXU/FX2C FX0N FX0(S)
Instruction
name
Operation
Execution
form
Expression in each language
Structured ladder ST
BINDA 16 bits Continuous BINDA(EN,s,d);
BINDAP 16 bits Pulse BINDAP(EN,s,d);
DBINDA 32 bits Continuous DBINDA(EN,s,d);
DBINDAP 32 bits Pulse DBINDAP(EN,s,d);
Variable Description
Data type
16-bit
operation
32-bit
operation
Input
variable
EN Execution condition Bit
Device storing binary data to be converted into ASCII codes ANY16 ANY32
Output
variable
ENO Execution state Bit
Head device storing conversion result String String
Operand
type
Bit Devices Word Devices Others
System user Digit specification Special unit
Special
unit
Index
Cons
tant
Real
Number
Character
String
Pointer
XYMTCS
D
.b
KnX KnY KnM KnS T C D R
U\G
VZModifierK H E
""
P
zz z zzzzz z zz z zz
zzz z z
BINDA
EN ENO
d
s
BINDAP
EN ENO
d
s
DBINDA
EN ENO
d
s
DBINDAP
EN ENO
d
s