2 Instruction List
2.3 Applied Instructions
36
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
*1. The instruction is provided in the FXU PLC Ver. 2.30 or later.
*2. The instruction is provided in the FX
U PLC Ver. 3.07 or later.
*3. The 32-bit operations are provided in the FX
3U and FX3UC PLCs Ver. 2.20 or later.
*4. The instruction is provided in the FX
U PLC Ver. 2.10 or later.
*5. The instruction is provided in the FX
0N PLC Ver. 1.20 or later.
*6. Though programmed, this instruction is not valid because the FX
1NC or FX2NC PLC does not have a
volume to read out under this instruction.
*7. The instruction is provided in the FX
U and FX2C PLCs Ver. 3.30 or later.
*8. The instruction is not provided in the FX
U and FX2C PLCs Ver. 3.30 or later.
*9. The instruction is provided in the FX
3UC PLC Ver. 2.20 or later.
*10. The instruction is provided in the FX
2N and FX2NC PLCs Ver. 3.00 or later.
*11. The instruction is provided in the FX
3UC PLC Ver. 1.30 or later.
*12. The instruction is provided in the FX
3G PLC Ver. 1.10 or later.
*13. The instruction is provided in the FX
3U and FX3UC PLCs Ver. 2.61 or later.
The FX
3UC-32MT-LT-2 PLC is due to be upgraded later.
Instruction name
Execution
condition
Function
Applicable PLCs
Reference
FX3U(C)
FX3G
FX2N(C)
FX1N(C)
FX1S
FXU/FX2C
FX0N
FX0(S)
External Device
RMRD Continuous
Read from F2-32RM
3
Section 7.10.6
RMRDP Pulse 3
DRMRD Continuous 3
DRMRDP Pulse 3
RMMN Continuous
F2-32RM monitor
3
Section 7.10.7
RMMNP Pulse 3
BLK Continuous
Specify F2-30GM
*8
Section 7.10.8
BLKP Pulse *8
MCDE Continuous
2-30GM code
*8
Section 7.10.9
MCDEP Pulse *8
Data Transfer 2
ZPUSH Continuous
Batch store of index register
3
Section 7.11.1
ZPUSHP Pulse 3
ZPOP Continuous
Batch POP of index register
3
Section 7.11.2
ZPOPP Pulse 3
Floating Point
DECMP Continuous
Floating point compare
3 *12 3
Section 7.12.1
DECMPP Pulse 3 *12 3
DEZCP Continuous
Floating point zone compare
33
Section 7.12.2
DEZCPP Pulse 33
DEMOV Continuous
Floating point move
3 *12
Section 7.12.3
DEMOVP Pulse 3 *12
DESTR Continuous
Floating point to character string
conversion
3
Section 7.12.4
DESTRP Pulse 3
DEVAL Continuous
Character string to floating point
conversion
3
Section 7.12.5
DEVALP Pulse 3
DEBCD Continuous
Floating point to scientific notation
conversion
33
Section 7.12.6
DEBCDP Pulse 33
DEBIN Continuous
Scientific notation to floating point
conversion
33
Section 7.12.7
DEBINP Pulse 33
DEADD Continuous
Floating point addition
3 *12 3
Section 7.12.8
DEADDP Pulse 3 *12 3