7 Applied Instructions
7.8 External FX I/O Device
387
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
OUT_T(X , TC0, D300);
Y015 X003
Write
in
Setting
MOVP
EN
s
ENO
d
D511
D300Z
[ ST ]
From previous page
OUT_T(X , TC1, D301);
OUT_T(X , TC99, D399);
M0:= X000;
M1:= X001;
M2:= X002;
M3:= NOT M8000;
ALTP(X004, M100);
Y014:= NOT M100;
Y015= M100;
IF(Y014 AND X003) THEN DSW (TRUE, X010, K1, Y010, Z);
SEGL(Y014, T0Z, K1, Y000);
MOVP(Y015, D300Z, D511);
ARWS(Y015, M0, K1, D511, Y000);
IF(Y015 AND X003) THEN MOVP(TRUE, D511, D300Z);