EasyManua.ls Logo

Mitsubishi Electric MELSEC FX Series - Page 609

Mitsubishi Electric MELSEC FX Series
838 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Applied Instructions
7.18 Others
607
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
2) 8-bit conversion mode [M8161 = ON]
In this mode, the operation is executed only for low-order 8 bits (low-order byte) of device specified by
.
With regard to the operation result, low-order 8 bits (byte) are stored to a device specified by , and
high-order 8 bits (byte) are stored to a device specified by +1.
2. Related devices
*1. Cleared when the PLC mode is changed from RUN to STOP.
Cautions
1) In this instruction, "X
16
+ X
15
+ X
2
+ 1" is used as a polynomial for generating the CRC value (CRC-16).
There are many other standard polynomials for generating the CRC value. Note that the CRC value
completely differs if an adopted polynomial is different.
Reference: Major polynomials for generating the CRC value
2) Some restrictions to applicable devices
S: Be sure to specify four digits for the bit devices (K4
).
Example: = D100
=D0
n=6
Device Contents of target data
Device storing data
for which the CRC
value is generated
Low-order byte Low-order bits of D100 01H
+1
Low-order byte Low-order bits of D101 03H
+2
Low-order byte Low-order bits of D102 03H
+3
Low-order byte Low-order bits of D103 02H
+4
Low-order byte Low-order bits of D104 00H
+5
Low-order byte Low-order bits of D105 14H
...
-
+n-1
Low-order byte -
Device storing the
generated CRC
value
Low-order byte Low-order bits of D0 E4H
+1
Low-order byte Low-order bits of D1 41H
Related devices Description
M8161
*1
ON CRC instruction operates in the 8-bit mode.
OFF CRC instruction operates in the 16-bit mode.
Name Generating polynomial
CRC-12
X
12
+ X
11
+ X
3
+ X
2
+ X + 1
CRC-16
X
16
+ X
15
+ X
2
+ 1
CRC-32
X
32
+ X
26
+ X
23
+ X
22
+ X
16
+ X
12
+ X
11
+ X
10
+ X
8
+ X
7
+ X
5
+ X
4
+ X
2
+ X + 1
CRC-CCITT
X
16
+ X
12
+ X
5
+ 1
Command input
M8161
M8000
8-bit conversion mode
CRC
EN ENO
d
s
n
*1
*2
*3
Device storing the generated CRC value*3.
Number of 8-bit (byte) data for which the CRC value is
generated or the device storing the number of data
*2.
Head device storing data for which the CRC value
is generated
*1.

Table of Contents

Other manuals for Mitsubishi Electric MELSEC FX Series