7 Applied Instructions
7.21 Data Operation 3
680
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
Program examples
In the program example shown below, the contents of Y010 to Y023 are shifted rightward by the number of
bits specified by D0 when X020 turns ON.
X020
SFRP
EN
n
ENO
d
K3Y010D0
[Structured ladder] [ST]
SFR(X020,D0,Y3Y010);
1 0 1 0 1 0 1 0 1 0 1 0
1
Carry flag
M8022
0 0 0 0 1 0 1 0 1 0 1 0
Becomes "0".
4
D0
Y23 Y20 Y17 Y14 Y13 Y10
Y23 Y20 Y17 Y14 Y13 Y10