7 Applied Instructions
7.21 Data Operation 3
683
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
Program examples
In the program example shown below, the contents of Y010 to Y017 are shifted leftward by the number of bits
specified by D0 when X020 turns ON.
X020
SFLP
EN
n
ENO
d
K2Y10
D0
[Structured ladder] [ST]
SFLP(X020,D0,K2Y10);
0 0 1 1 0 0 1 1
1 0 0 1 1 0 0 01
Carry flag
M8022
Becomes "0".
Y17 Y14 Y13 Y10
Y17 Y14 Y13 Y10
Y12
3
D0

Table of Contents