7 Applied Instructions
7.28 FX3U-CF-ADP
801
FXCPU Structured Programming Manual
(Basic & Applied Instruction)
1
Outline
2
Instruction List
3
Configuration of
Instruction
4
How to Read
Explanation of
Instructions
5
Basic Instruction
6
Step Ladder
Instructions
7
Applied
Instructions
8
Interrupt Function
and Pulse Catch
Function
A
Relationships
between devices
and addresses
Detailed explanation of setting data
Details of the setting data in the FLCMD instruction are as shown below.
*1. The CompactFlash
TM
card is available in the "mounted" status.
*2. The CompactFlash
TM
card is unavailable in the "unmounted" status.
Caution
1) The FX3U and FX3UC PLCs supports the instruction at V2.61 or later.
The FX
3UC-32MT-LT-2 PLC is due to be upgraded later.
Setting items Description Data Type
Contents of instruction for operation
K-1 : Forcibly writes all buffered data to the CompactFlash
TM
card.
K0 to K63 : Forcibly writes the buffered data of the specified file ID to the CompactFlash
TM
card.
K256(H100) : Sets the CompactFlash
TM
card to the mounted status
*1
.
K512(H200) : Sets the CompactFlash
TM
card to the unmounted status
*2
.
K1280(H500) : Clears error codes stored in the CF-ADP.
ANY16
Channel number used by the CF-ADP
K1 : ch1
K2 : ch2
ANY16

Table of Contents