14
2 HIGH-SPEED COUNTER MODULE FB
2.2 M+FX5-2HC_PulseMeasure (Pulse Width Measurement)
FB details
Available device
Basic specifications
Processing
By turning on i_bEN (Execution command), pulse measurement is performed as set in i_uInputSignal (Input signal).
After i_bEN (Execution command) turns on, o_bOK (Normal completion) turns on when pulse width measurement of the
target channel starts.
When o_bOK (Normal completion) is on, if the pulse width measurement value of the target channel is updated,
o_bPulseUpdate (Pulse width measurement update flag) is turned on, and the updated value is stored in o_dPulseResult
(Pulse width measurement value).
When o_bOK (Normal completion) is on, if the period measurement value of the target channel is updated,
o_bPeriodUpdate (Period measurement value update flag) is turned on, and the updated value is stored in
o_dPeriodResult (period measurement value).
o_bPulseUpdate (Pulse width measurement update flag) and o_bPeriodUpdate (Period measurement value update flag)
are on for only one scan.
Target module Firmware Version Engineering tool
FX5UJ CPU module 1.060 or later GX Works3 Version 1.100E or later
FX5U CPU module 1.300 or later GX Works3 Version 1.100E or later
FX5UC CPU module 1.300 or later GX Works3 Version 1.100E or later
High-speed counter module 1.000 or later GX Works3 Version 1.100E or later
Item Description
Language Ladder diagram
Number of steps 832 steps
The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions,
and the options setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The amount of label usage Label: 340 points (Word)
Latch label: 0 points (Word)
The amount of labels used in the program varies depending on the CPU module used, the device specified in an
argument, and the option setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The number of index register
usage
Index register: 0 points
Long index register: 0 points
The amount of file register usage File register: 0 points (Word)
FB dependence No dependence
FB compilation method Macro type
FB operation Always executed