2 HIGH-SPEED COUNTER MODULE FB
2.5 M+FX5-2HC_ErrorOperation (Error Operation)
29
2
FB details
Available device
Basic specifications
Processing
By turning on i_bEN (Execution command), error monitoring of the target channel is executed.
o_bMonitorOK (Monitoring status) turns on when the target channel is being monitored.
If an error occurs, o_bUnitError (Module error detection) turns on, and the error code is stored in o_uUnitErrCode (Module
error code).
After i_bEN (Execution command) turns on, i_bErrorReset (Error reset command) is turned on while the error is occurring,
and error reset is executed.
After error reset is completed, o_bOK (Normal completion) turns on.
Target module Firmware Version Engineering tool
FX5UJ CPU module 1.060 or later GX Works3 Version 1.100E or later
FX5U CPU module 1.300 or later GX Works3 Version 1.100E or later
FX5UC CPU module 1.300 or later GX Works3 Version 1.100E or later
High-speed counter module 1.000 or later GX Works3 Version 1.100E or later
Item Description
Language Ladder diagram
Number of steps 305 steps
The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions,
and the options setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The amount of label usage Label: 336 points (Word)
Latch label: 0 points (Word)
The amount of labels used in the program varies depending on the CPU module used, the device specified in an
argument, and the option setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The number of index register
usage
Index register: 0 points
Long index register: 0 points
The amount of file register usage File register: 0 points (Word)
FB dependence No dependence
FB compilation method Macro type
FB operation Always executed