EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-F Series - Cyclic Transmission

Mitsubishi Electric MELSEC iQ-F Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
2 HIGH-SPEED COUNTER MODULE FB
2.4 M+FX5-2HC_RotationSpeedMeasure (Rotation Speed Measurement)
FB details
Available device
Basic specifications
Processing
By turning on i_bEN (Execution command), the rotation speed calculated based on the values of CH1 measurement unit
time (Un\G228 to Un\G229)/CH2 measurement unit time (Un\G428 to Un\G429), CH1 number of pulses per rotation
(Un\G230 to Un\G231)/CH2 number of pulses per rotation (Un\G430 to Un\G431) is read from the buffer memory.
After i_bEN (Execution command) turns on, o_bOK (Normal completion) turns on when rotation speed measurement of the
target channel starts.
When o_bOK (Normal completion) is on, if the rotation speed of the target channel is updated, o_bUpdate (Rotation speed
measurement value update flag) is turned on, and the updated value is stored in o_dRotationVal (Rotation speed
measurement value).
o_bUpdate (Rotation speed measurement value update flag) is on for only one scan.
Target module Firmware Version Engineering tool
FX5UJ CPU module 1.060 or later GX Works3 Version 1.100E or later
FX5U CPU module 1.300 or later GX Works3 Version 1.100E or later
FX5UC CPU module 1.300 or later GX Works3 Version 1.100E or later
High-speed counter module 1.000 or later GX Works3 Version 1.100E or later
Item Description
Language Ladder diagram
Number of steps 570 steps
The number of steps of the FB embedded in a program depends on the CPU module used, the input/output definitions,
and the options setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The amount of label usage Label: 336 points (Word)
Latch label: 0 points (Word)
The amount of labels used in the program varies depending on the CPU module used, the device specified in an
argument, and the option setting of GX Works3. For the option settings of GX Works3, refer to the following.
GX Works3 Operating Manual
The number of index register
usage
Index register: 0 points
Long index register: 0 points
The amount of file register usage File register: 0 points (Word)
FB dependence No dependence
FB compilation method Macro type
FB operation Always executed

Other manuals for Mitsubishi Electric MELSEC iQ-F Series

Related product manuals