Model: PUMY-P60NKMU (-BS)
Model Name
Unit Type PUMY-P60NKMU (-BS)
Nominal Cooling Capacity Btu/h 60,000
Nominal Heating Capacity Btu/h 66,000
Operating Temperature Range
Cooling (Outdoor) *1
23° F ~ 115° F (-5 ° ~ +46° C) DB*
Heating (Outdoor)
-4° F ~ +60° F (-20 ° ~ +15° C) WB
External Dimensions (H x W x D) In. / mm 52-11/16 x 41-5/16 x 13 (+1-3/16) / 1,338 x 1050 x 330 (+30)
Net Weight Lbs. / kg 313 / 142
Electrical Power Requirements Voltage, Phase, Hertz
208 / 230V, 1-phase, 60Hz
Cooling Power Input kW 4.80
Heating Power Input kW 6.15
Cooling Current A 21.5
Heating Current A 27.6
Minimum Circuit Ampacity (MCA) A 35
Recommended Fuse/Breaker Size A 40
Maximum Fuse Size A 42
Piping Diameter (Brazed) (In. / mm)
Liquid (High Pressure) 3/8 / 9.52
Gas (Low Pressure) 3/4 / 19.05
Indoor Unit
Total Capacity 50 to 130% of Outdoor Unit Capacity
Model / Quantity P06 to P72 / 1 to 12
Sound Pressure Levels dB(A) 58/59
Fan
Type x Quantity Propeller Fan x 2
CFM 4,940
Compressor Operating Range 22% to 100%
Compressor Type x Quantity INVERTER-driven Scroll Hermetic x 1
Compressor Motor Output kW 3.0
Refrigerant R410A
Lubricant FV50S
High-pressure Protection Device High Pressure Switch
Compressor / Fan Protection Device Compressor Thermo / Overcurrent Detection
Inverter Protection Device Overheat / Voltage Protection
AHRI Ratings
(Ducted / Non-Ducted)
EER 11.3 / 12.5
SEER 16.5 / 16.7
COP 3.70 / 3.14
Blue Fin Anti-corrosion Protection: Cellulose- and polyurethane-resin coating treatment applied to condenser coil that protects it from air contaminants;
1μm thick; Salt Spray Test Method - no unusual rust development to 960 hours.
SEACOAST PROTECTION
External Panel Base, External Front Panel, Pillar: Alloyed galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces
Compressor Cover: Galvanized-aluminum sheets with thermoset polyester-resin coating on internal and external surfaces
Electrical Parts Box: Galvanized-aluminum sheets with thermoset polyester-resin coating on external surface
Fan Motor Support: Galvanized-steel sheets with thermoset polyester-resin coating on internal and external surfaces
Printed Circuit Board: Epoxy resin with polyurethane-coating on external surface
OUTDOOR VRF SYSTEM FEATURES
zoning technology
Inverter-driven (variable speed) compressor
Total refrigerant piping length of 492' (150 m)
Uses CITY MULTI indoor units and Controls Network
UNIT OPTION
Standard Model………………….....PUMY-P60NKMU
Sea Coast (BS) Model…………......PUMY-P60NKMU-BS
OPTIONAL PARTS
Branch Joint (T-Branch)………………………………...CMY-Y62-G-E
Header - Four-Branch…………………………………......CMY-Y64-G-E
Header - Eight-Branch…………………………………..CMY-Y68-G-E
Base Heater………………………………........ PAC-SJ19BH-E
NOTES:
*1 If PKFY-P06/08 indoor units are connected, then range is 50° F ~ 115° F (10° C ~ 46° C).
PUMY-P60NKMU (-BS)
Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Electric PUMY-P60NKMU and is the answer not in the manual?

Mitsubishi Electric PUMY-P60NKMU Specifications

General IconGeneral
Cooling Capacity6.0 kW
RefrigerantR410A
HSPF4.20
SeriesPUMY
Power Supply220-240V

Summary

Outdoor VRF System Features

Unit Option

Specifications

Operating Temperature Range

Operating temperature range: Cooling (Outdoor) 23-115°F DB, Heating (Outdoor) -4-60°F WB.

Electrical Power Requirements

Requires 208/230V, 1-phase, 60Hz electrical power supply.

Piping Diameter

Piping diameters: 3/8" for liquid (high pressure) and 3/4" for gas (low pressure).

AHRI Ratings

AHRI ratings include EER (11.3/12.5), SEER (16.5/16.7), and COP (3.70/3.14).

Blue Fin Anti-corrosion Protection

Seacoast Protection

Protected Components

Details protection for external panels, compressor cover, electrical box, fan motor support, and circuit board.

Dimensions

Installation Clearances

Diagrams illustrate required free space for installation and service access.

Foundation Bolts

Specifies the need for M10 (3/8") foundation bolts for secure unit mounting.

Piping and Wiring Directions

Indicates that piping and wiring connections can be made from four directions: front, right, rear, and below.

Piping Knockout Hole Details

Illustrates specific knockout hole sizes and locations for piping and conduit connections.

Related product manuals