476
Appendix 3.3 Factors that increase the scan time
When executing any of the functions or operations described in this section, add the given processing time in this
section to the time value calculated in Page 466, Appendix 3.1.
(1) Sampling trace
When the sampling trace function ( Page 182, Section 3.14) is executed, the processing time listed in the
following table is required.
[Conditions] Processing time (when 50 points of the internal relay (for bit device) and 50 points of the data register
(for word device) are set as sampling trace data)
*1 When specifying devices in the trigger point setting, the scan time may be increased by up to 0.163µs per instruction.
CPU module Processing time
Standard RAM
Q00UCPU, Q01UCPU 0.12ms
Q02UCPU 0.09ms
Q03UD(E)CPU
0.07ms
*1
Q04UD(E)HCPU, Q06UD(E)HCPU, Q10UD(E)HCPU,
Q13UD(E)HCPU, Q20UD(E)HCPU, Q26UD(E)HCPU
0.06ms
*1
Q50UDEHCPU, Q100UDEHCPU 0.06ms
Q03UDVCPU
0.045ms
*1
Q04UDVCPU, Q06UDVCPU, Q13UDVCPU,
Q26UDVCPU
0.045ms
*1
Standard RAM
(with an extended
SRAM cassette)
Q03UDVCPU, Q04UDVCPU, Q06UDVCPU,
Q13UDVCPU, Q26UDVCPU
0.05ms
*1
SRAM card
Q02UCPU 0.09ms
Q03UD(E)CPU
0.08ms
*1
Q04UD(E)HCPU, Q06UD(E)HCPU, Q10UD(E)HCPU,
Q13UD(E)HCPU, Q20UD(E)HCPU, Q26UD(E)HCPU
0.06ms
*1
Q50UDEHCPU, Q100UDEHCPU 0.06ms

Table of Contents