Appendix 1 Error Codes
Appendix 1.3 List of error codes (1000 to 1999)
1002
[MAIN CPU DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: Failure information
(QnUDVCPU only)
Diagnostic timing
Always
Take noise reduction measures.
Reset the CPU module and run it again. If
the same error code is displayed again, the
cause is a hardware failure of the CPU
module. Please consult your local
Mitsubishi representative.
RUN: Off
ERR.:Flashing
CPU Status:Stop
QCPU
[CPU UNIT DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: Failure information
Diagnostic timing
Always
LCPU
1003
[MAIN CPU DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: Failure information
(QnUDVCPU only)
Diagnostic timing
Always
Take noise reduction measures.
Reset the CPU module and run it again. If
the same error code is displayed again, the
cause is a hardware failure of the CPU
module. Please consult your local
Mitsubishi representative.
RUN: Off
ERR.:Flashing
CPU Status:Stop
QCPU
[CPU UNIT DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: Failure information
Diagnostic timing
Always
LCPU
1004
[MAIN CPU DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: -
Diagnostic timing
Always
Take noise reduction measures.
Reset the CPU module and run it again. If
the same error code is displayed again, the
cause is a hardware failure of the CPU
module. Please consult your local
Mitsubishi representative.
RUN: Off
ERR.:Flashing
CPU Status:Stop
QCPU (except
QnUDV)
[CPU UNIT DOWN]
Runaway or failure of the CPU module
Malfunction due to noise or other causes
Hardware failure
Collateral information
Common information: -
Individual information: Failure information
Diagnostic timing
Always
LCPU
Error
code
Error and cause Corrective action
LED status,
CPU status
Corresponding