502
SM1910
CH2
coincidence
signal No.1
reset command
Resets CH2 counter
value coincidence No.1.
This relay is turned on to reset CH2
counter value coincidence No.1.
The command is valid while this relay is
on.
The on time must be held for at least 2ms.
UNewLCPU
SM1911
CH2
coincidence
signal No.2
reset command
Resets CH2 counter
value coincidence No.2.
This relay is turned on to reset CH2
counter value coincidence No.2.
The command is valid while this relay is
on.
The on time must be held for at least 2ms.
UNewLCPU
SM1912
CH2
coincidence
output enable
command
Controls outputs from
CH2 coincidence output
No.1 and No.2 terminals.
This relay is turned on to perform
coincidence output from CH2 coincidence
output No.1 and CH2 coincidence output
No.2 terminals.
The command is valid while this relay is
on.
UNewLCPU
SM1913
CH2 preset
command
Presets the counter
value.
This relay is turned on to preset the
counter value.
The command is valid at the rise of this
relay (off on).
The on and off time must be held for at
least 2ms.
UNewLCPU
SM1914
CH2 count down
command
Counts down pulses.
This relay is turned on to count down
pulses.
The command is valid while the Pulse
input mode is either 1-phase multiple of n
or 1-phase multiple of n (A phase only).
The command is valid while this relay is
on.
UNewLCPU
SM1915
CH2 count
enable
command
Starts counting.
This relay is turned on to start counting.
The command is valid while this relay is
on.
UNewLCPU
SM1916
CH2 counter
function
selection start
command
Starts the selected
counter function.
This relay is turned on to start the
selected counter function.
When the count disabling function is
selected, the command is valid while this
relay is on.
When the latch counter function or the
sampling counter function is selected, the
command is valid at the rise of this relay
(off on). The on time must be held for
at least 2ms.
When the count disabling/preset function
or the latch counter/preset function is
selected, the command is invalid.
UNewLCPU
SM1917
CH2 external
preset (phase Z)
request
detection reset
command
Resets CH2 external
preset (phase Z) request
detection.
This relay is turned on to reset CH2
e
xternal preset (phase Z) request
detection.
The command is valid at the rise of this
relay (off on).
The on and off time must be held for at
least 2ms.
UNewLCPU
SM1918
CH2 pulse
measurement
start command
Starts pulse
measurement.
This relay is turned on to measure pulses.
The command is valid while this relay is
on.
UNewLCPU
SM1919
CH2 error reset
command
Resets the CH2 error.
This relay is turned on to reset the CH2
error.
The command is valid at the rise of this
relay (off on).
The on and off time must be held for at
least 2ms.
UNewLCPU
Number Name Meaning Explanation
Set by
(When Set)
Corresponding
ACPU
M9
Corresponding
CPU