Appendix 8 EMC and Low Voltage Directives
Appendix 8.1 Requirements for compliance with the EMC Directive
To supply the module power supply terminal of the AJ65BTB2-16R/16DR, AJ65SBTB2N-
8A/8R/8S/16A/16R/16S with power using the AC/DC power supply, follow as shown below.
Install the AC/DC power supply in the control panel where the module is installed.
Use a CE-marked AC/DC power supply and ground the FG terminals.
(The AC/DC power supply used for the tests conducted by Mitsubishi: TDK-Lambda Corporation: DLP-
120-24-1)
For the cable connected to the AC input terminal and DC output terminals of the AC/DC power supply,
attach a ferrite core. Twist the cable around the ferrite core by one as shown below.
(Ferrite core used for the tests conducted by Mitsubishi: NEC TOKIN Corporation: ESD-SR-250)
(7) CC-Link/LT module
To supply the CL2DA2-B and CL2AD4-B with power using the CL1PAD1, keep the length of the power cable
connected from the CL1PAD1 to the external power supply to 30m or less.
(8) Positioning module
Use the cables with following length when connecting a drive unit to the QD75.
Use the cable whose length is 30m or less when connecting it to an external device for the QD75. (except for
a pulse output)
(9) 4Mpps capable high-speed counter module
Keep the length of a power cable connected to the external coincidence output power supply terminal to 10m
or less.
Keep the length of a cable connected to an external device to 30m or less.
(10)Multi function counter/timer module
Install the DC power connected to the encoder inside the same control panel where the module is installed.
Install a ferrite core to each DC power cable connected to the module and the controller.
The ferrite core ZCAT3035-1330 (TDK Corporation) is recommended.
Keep the length of a cable connected to the encoder to 3m or less.
Keep the length of a cable connected to the controller or external output terminal to 30m or less.
Keep the length of a DC power cable connected to the external device to 3m or less.
QD75PN/QD75P : 2m or less
QD75DN/QD75D : 10m or less