PARTS CATALOG (OCB709)
CONTENTS
1.
COMBINATION OF INDOOR AND OUTDOOR UNITS
...
2
2. PART NAMES AND FUNCTIONS
......................
2
3. SPECIFICATION
.................................................
3
4. OUTLINES AND DIMENSIONS
..........................
4
5. WIRING DIAGRAM
............................................
5
6. REFRIGERANT SYSTEM DIAGRAM
................
7
7. DATA
...................................................................
9
8. ACTUATOR CONTROL
.....................................
14
9. SERVICE FUNCTIONS
......................................
15
10. TROUBLESHOOTING
.......................................
15
11. FUNCTION SETTING
........................................
32
12. DISASSEMBLY INSTRUCTIONS
......................
35
Note:
This manual describes
service data of the outdoor
units only.
No. OCH709
REVISED EDITION-A
December 2019
SPLIT-TYPE, AIR CONDITIONERS
SUZ-KA09NAHZ.TH
OCH709 is void.
Revision:
3.SPECIFICATION has
been revised in REVISED
EDITION-A.

Questions and Answers:

Mitsubishi Electric SUZ-KA09NAHZ Specifications

General IconGeneral
BrandMitsubishi Electric
ModelSUZ-KA09NAHZ
CategoryAir Conditioner
LanguageEnglish

Summary

1. COMBINATION OF INDOOR AND OUTDOOR UNITS

2. PART NAMES AND FUNCTIONS

3. SPECIFICATION

OPERATING RANGE

Details the operating parameters and voltage limits for the outdoor units.

4. OUTLINES AND DIMENSIONS

REQUIRED SPACE

Specifies the minimum clearance needed around the outdoor unit for proper ventilation.

5. WIRING DIAGRAM

6. REFRIGERANT SYSTEM DIAGRAM

MAX. REFRIGERANT PIPING LENGTH and MAX. HEIGHT DIFFERENCE

ADDITIONAL REFRIGERANT CHARGE (R410A: oz.)

Information on when additional refrigerant is required based on piping length.

7. DATA

STANDARD OPERATION DATA

Presents operational data like capacity, input, pressures, and temperatures for various models.

8. ACTUATOR CONTROL

8-1. OUTDOOR FAN MOTOR CONTROL

Describes the ON/OFF timing of the outdoor fan motor relative to the compressor.

8-2. R.V. COIL CONTROL

Explains the control sequence for the 4-way reversing valve coil.

8-3. RELATION BETWEEN MAIN SENSOR AND ACTUATOR

Details how sensors interact with actuators like compressor, LEV, and motors.

9. SERVICE FUNCTIONS

9-1. CHANGE IN DEFROST SETTING

Instructions for adjusting the defrost finish temperature via jumper settings.

9-2. PRE-HEAT CONTROL SETTING

How to activate pre-heat control to prevent compressor start-up issues in cold weather.

10. TROUBLESHOOTING

10-1. CAUTIONS ON TROUBLESHOOTING

Safety precautions and general checks before starting troubleshooting procedures.

10-2. TROUBLESHOOTING CHECK TABLE

A table listing LED error codes, symptoms, conditions, and remedies for troubleshooting.

10-3. HOW TO PROCEED "SELF-DIAGNOSIS"

10-3-1. Self-diagnosis <PAR-4xMAA ("x" represents 0 or later)>

Steps to perform self-diagnosis and reset error history via the remote controller.

10-3-2. Remote controller check <PAR-4xMAA ("x" represents 0 or later)>

Procedure for diagnosing issues with the remote controller's communication.

10-3-3. Malfunction-diagnosis method by IR wireless remote controller

How to use the IR remote controller to diagnose malfunctions by checking error codes.

10-4. TROUBLE CRITERION OF MAIN PARTS

10-5. TROUBLESHOOTING FLOW

10-6. TEST POINT DIAGRAM AND VOLTAGE

11. FUNCTION SETTING

11-1. UNIT FUNCTION SETTING BY THE REMOTE CONTROLLER

Guide to setting unit functions using the remote controller interface.

11-1-1. Selecting functions using the wired remote controller (PAR-4xMAA)

12. DISASSEMBLY INSTRUCTIONS

Disassembly: Inverter Assembly and R.V. Coil Procedures

2. Removing the inverter assembly, inverter P.C. board

Steps for removing the inverter assembly and its main printed circuit board.

3. Removing R.V. coil

Procedure for safely disconnecting and removing the reversing valve (R.V.) coil.

Disassembly: Sensors, Fan Motor, Compressor & Valve Procedures

4. Removing Temperature Sensors

Instructions for removing various temperature sensors from the outdoor unit.

5. Removing outdoor fan motor

Detailed steps for safely removing the outdoor fan motor assembly.

6. Removing the compressor and 4-way valve

Procedures for removing the compressor and the 4-way valve, including gas recovery.