OIL PAN AND OIL PUMP
ENGINE OVERHAUL <4G63-Turbo>
11D-54
OIL COOLER BY-PASS VALVE
1. Make sure that valve moves smoothly.
2. Ensure that the dimension L measures the
standard value under normal temperature and
humidity.
Standard value: 34.5 mm
3. The dimension must be the standard value when
measured after the valve has been dipped in 97 to
103°C oil.
Standard value: 40.0 mm
AK000032
L
Valve
AC