2. 
NOMENCLATURE 
AND 
FUNCTIONS 
Removing and Attaching  the  Acc08sory 
Cover 
Insert the tip of a screw driver into the 
slot 
at the  right side 
of 
the 
inverter and pull the handle of  the screw driver  up 
around the slot  to  loosen cover. 
Pull the  cover toward you to  T%moye. 
To attach  the accessory cover, insert  the  left edge of  the 
cover into  the  slot  in  the  inverter  and push the right side 
of 
the 
cover against the inverter. 
Handling 
th. 
FFbARW03 
Par#rwtr 
Copy 
Unk 
The FR-ARWOS parameter copy unit can 
be 
connected to  the inverter  directly  or  with an op- 
tional  cable.  Options,  function settings, and operation  status  monitoring mn 
be 
done, the 
same 
as with the FR-PUO3. Note that the function assigned to the 
@ 
key on the FR-ARW03  dif- 
fers 
from that  on the  FR-PUO3. 
With the FR-ARW03 
it 
is possible to read 
the 
inverter parameters set  for individual  applications 
collectively  and  to copy them to other  inverters. 
Note:  1. 
Do 
not copy the parameters between differing  voltage classes or differing  capacities. 
If 
the  parameters are copied between differing  voltage  classes or differing  capacities, 
the  motor  rotation  may  become  unstable,  unexpected alarms  may  occur,  or  the 
inverter‘s performance  may 
be 
acheved.  Contact  Mitsubishi if  the  parameters  are 
copied by  mistake. 
2. 
If 
copying the parameters from old version to  new  version,  the set value of  Pr.31  and 
Pr.81  changes.  After  parameter copy from old version to  new  version,  manually set 
“0” 
to  Pr.31 and set 
‘9999” 
to  Pr.81  in new version. 
Please see the following 
serial 
number  to distinguish new version. The serial number 
is shown  on  the name  plate.  New version has the  same or higher number. 
FR-A024-0.1K 
lo 
1.5K 
-6-