11. 
OPERATION 
11.1 
Operation 
Modes 
The  operation  mode 
of 
the  inverter  is  classified  into  the  following  three  modes 
- 
the  external 
operation  mode  in  which the inverter  operation  is  controlled by the  external  signals,  the 
PU 
opera- 
tion  mode  in which the inverter  operation  is  controlled  by  the  parameter  unit,  and  the  combined 
operation  mode in which  the  inverter  operation  is  controlled by  both 
the 
externals  signals  and  the 
parameter  unit. 
Factory-set operation 
mode 
When  power  is  turned 
ON 
or 
when  the  in- 
verter is  reset, the  operation  mode  is  set  to 
"operation  using  external  input  slgnals". 
Therefore,  the  inverter  can  be  operated  using 
the  external  signals  when 
it 
is  tumed 
ON. 
The 
inverter  starts  operating  if  the  start  signal 
(STF/STR and 
SD) 
is  turned 
ON 
in  this  state. 
A 
speed  reference  signal  is  also  required  for 
motor rotation. 
To 
fix the  operation 
mode 
it is  possible to  set  the  operation  mode which 
is  established  when  power  is turned 
ON. 
For 
example, if the  inverter  needs  to 
be 
operated 
only in  the  PU operation  mode,  it  is  possible 
to set  the  PU  operation  mode  as  the  mode to 
be 
estaMished  when  power  is  tumed 
ON. 
In 
this  state,  there  is no  need to  press  the  opera- 
the 
paramam 
unll. 
devm 
(frequency 
sen~ng 
varlabl 
operation  mode  aiter  turning 
ON 
power. 
* 
Freqwncy 
IS 
$91 
mth 
an 
0Iternal 
tion  mode  selection  key  to 
select 
the  PU 
The procedure to  set  the  default  mode for the 
mode  which  is  established  when  power  is 
turned on 
is 
explained  on  page 
27. 
- 