9. 
PRECAUTIONS 
ON 
OP6RATWG 
THE 
RARAMHERWCT 
~~  ~~  ~~~~ 
When 
operating  the  parameter 
unit, 
if 
review 
ttm 
following  precautions 
- 
- 
the 
set value  cannot 
be 
writtin or  a  wmg value 
is 
witten. 
.. 
(1) 
Plscattionr  for 
operating 
the 
in- 
verter 
by 
the 
parameter 
unit 
lnvetter Operation uslng  the  parameter 
unit  is  enabled  only  when  the 
[PU OP] 
key  is  pressed  or  the 
PU 
operation or 
combination  operation  mode  is  selected 
by 
Pr. 
79. 
In the  monitor  mode 
(MONITORrode 
lamp  is  lit),  the  operation 
cannot 
be 
set. 
(blinks) 
\+ 
(unsl) 
In 
the 
fdbwing 
cases, 
jog  operation  is 
not  possible. 
(1) 
While  the  motor  is  running. 
(blinks) 
(MnkS) 
To 
execute  jog  operation,  stop  the 
motor  first. 
(2) 
If 
the  setting  for 
jog 
frequency  (Pr. 
15) 
is  lower  than  the  setting  for 
operation  start  frequency  (Pr. 
13). 
- 
(2) 
Precautions 
for 
monitoring 
- 
While  operating  the  motor  from  the 
parameter  unit,  when  the  start  key 
([FWD] 
or 
[REV) 
is  pressed  after  set- 
ting 
the 
operation  frequency,  the  mode 
automticalty 
switches  to  the  monitor 
mode. 
- 
(3) 
Precautions 
for 
operation 
- 
r 
In 
the 
fobwing 
cases, 
the  operation 
mode  cannot  be  switched  by  pressing 
the 
[PU OP] 
or 
[EXT 
OP] 
key. 
(1) 
While  the  motor  is  running. 
(4) 
Precautions  for 
the 
number 
of 
- 
r 
digits 
and a decimal 
point 
(2) 
The  external  start  signal  (across 
terminals STR  or  STF,  and 
SD) 
is 
ON. 
(3) 
The  setting  for  operation  mode 
selection  (Pr. 
79) 
is any of  the  fol- 
lowing  values. 
Set  value: 
1 
to 
4, 
7, 
8 
If 
"0" is  set for operation  mode  selection 
(Pr. 
79), 
the  external  operation 
mode 
is 
established if  the following  is  attempted 
- 
turning 
off 
power  supply to the  inverter 
and then  turn  it  on again,  or  resetting. 
Precautions  for 
the 
number 
of 
- 
digits 
and a decimal 
polnt 
The  maximum  number 
of 
digits  for  a 
value to 
be 
input  is 
4. 
It  a  value  is  input 
exceeding  this  limit, the  most  significant 
digit is ignored. See the  example  below. 
Display 
on 
1 
23 
4 
s 
-8 
-, 
the 
parameter 
(input) 
i~gnored 
(5) 
Precautions  for  setting  the 
operating  frequency 
When  the  operation  frequency  has 
been  set  using  the 
[A] 
and 
p] 
keys 
(step  setting)  or  directly  (direct  setting), 
setting  is  allowed  only  in the range  es- 
tablished  by the  upper  limit  and  lower 
limit  frequencies. 
-22-