4. OPERATING RANGE
1) POWER SUPPLY
2) OPERATION
5. OUTLET AIR SPEED AND COVERAGE RANGE
The air coverage range is the value up to the position where the air speed is 0.8ft/sec. when air is blown out
horizontally from the unit at the High fan setting.
The coverage range should be used only as a general guideline since it varies according to the size of the
room and furniture installed inside the room.
6. ADDITIONAL REFRIGERANT CHARGE (R22 (oz))
Indoor unit
Outdoor unit
Rating
115V 1 phase 60Hz
208/230V 1 phase 60Hz
Allowable voltage
Min. 103V — Max. 127V
Min. 198V — Max. 253V
Function
Cooling
D.B.(˚F)
80
95
67
80
Condition
Standard temperature
Maximum temperature
Minimum temperature
Maximum humidity
Indoor
Intake air temperature
Outdoor
W.B.(˚F)
67
71
57
75
D.B.(˚F)
95
115
*0
80
* With wind baffle D.B. 23˚F if no wind baffle.
W.B.(˚F)
75
75
75
Airflow
Air speed
Coverage range
(CFM)
(ft / sec.)
(ft)
Standard
height
(8.2ft)
490
14.1
32
710
16.1
41
710
16.1
41
990
17.7
50
990
17.7
50
PK12FK
PK12FK
1
PK18FK
PK18FK
1
PK18FK2
PK24FK
PK24FK
1
PK24FK2
PK30FK
PK30FK
1
PK30FK2
PK36FK
PK36FK
1
PK36FK2
Model
PK12FK, PK12FK1
PK18FK, PK18FK1, PK18FK2
PK24FK, PK24FK1, PK24FK2
PK30FK, PK30FK1, PK30FK2
PK36FK, PK36FK1, PK36FK2
4 lbs 14 oz
5 lbs 8 oz
9 lbs 15 oz
10 lbs 2 oz
10 lbs 9 oz
25ft
0
0
0
0
0
40ft
0
0
0
0
0
55ft
0
0
0
0
0
70ft
0
0
0
0
0
85ft
0
0
0
0
0
Refrigerant piping length (over way)
100ft
0
0
0
0
0
115ft
2
2
2
5
5
130ft
4
4
4
10
10
150ft
7
16
16
164ft
9
20
20
Outdoor unit
precharged
(up to 100ft)
OC196A--1.qxp 1.12.19 10:35 AM Page 17