23
PKFY-P63VKM-E.TH PKYF-P100VKM-E.TH
PKFY-P63VKM-ER1.TH PKFY-P100VKM-ER1.TH
1
2
3
4
5
6
7
8
9
10
1~6
1~4
1
2
3
4
5
6
7
8
Thermistor<Room temperature>
position
ON OFF
Filter clogging detection Provided Not provided
Filter cleaning sign 2,500 hr 100 hr
Fresh air intake Not effective Not effective
Switching remote controller display
Thermo ON signal indication
Fan output indication
Humidifier control
Fan operation at Heating mode
Thermo ON operation at
heating mode
Low *1 Extra low *1
Setting air flow *1 Depends on SW1-7
Auto restart function Effective Not effective
Power
ON/OFF by breaker
Effective Not effective
Heat pump/Cool only Cooling only Heat pump
Not used
Not used
Vane horizontal angle Second setting *1 First setting
Effective Not effective
Heating 4 degree up Not
ON
OFF
effective Effective
Target superheat setting
*2
——
——
Target subcool *2
ON
OFF
1234567 8
ON
OFF
12345678910
Address board
<Initial setting>
Indoor controller board
Indoor controller board
Indoor controller board
<Initial setting>
SW3
SW4
Model
Select
Function
selection
Under
suspension
SW2
Capacity
code
Before
power
supply
ON
Before
power
supply
ON
switch
SW1
Mode
Effective
timing
Under
suspension
selection
Switch Pole
Function
Operation by switch
Remarks
Built-in remote controller
Indoor unit
Changing the opening of linear
expansion valve during thermo OFF
*1
SW1-7
OFF
ON
OFF
ON
SW1-8
OFF
OFF
ON
ON
Fan speed
Extra low
Low
Setting air flow
Stop
*2 It is impossible to intake
the fresh air.
<Initial setting>
Set for each capacity
*1 Second setting is same as
first setting.
*2 Please do not change SW3-7
and 3-8.
Air flow set in case of heat
thermo OFF
NOTE:
*2
P63
123456
ON
OFF
P100
123456
ON
OFF
1234
0
5
9
4
8
3
7
2
6
1
SW12
10
0
5
9
4
8
3
7
2
6
1
SW11
1
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
SW14
0
5
9
4
8
3
7
2
6
1
SW12
0
5
9
4
8
3
7
2
6
1
SW11
0
8
F
7
E
6
D
5
C
4
B
3
A
2
9
1
SW14
Address board
Address board
<Initial setting>
<Initial setting>
SW11
1s digit
address
setting
SW12
10ths digit
address
setting
Rotary switch
SW14
Branch
No.
Setting
Rotary switch
How to set addresses
Example : If address is "3", remain SW12
(for over 10) at "0", and match SW11 (for 1 to 9)
with "3".
How to set branch numbers SW14 (Series R2 only)
Match the indoor unit’s refrigerant pipe with
the BC controller’s end connection number.
Remain other than series R2 at "0".
Before
power
supply
ON
8-2. Function of Dip switch
OCH447B