EasyManua.ls Logo

Mitsubishi PUHZ-SW75VHAPUHZ-SW100VHAPUHZ-SW100YHAPUHZ-SW120VHAPUHZ-SW120YHAPUHZ-SW75VHA-BSPUHZ-SW100VHA-BSPUHZ-SW100YHA-BSPUHZ-SW12 - Page 20

Mitsubishi PUHZ-SW75VHAPUHZ-SW100VHAPUHZ-SW100YHAPUHZ-SW120VHAPUHZ-SW120YHAPUHZ-SW75VHA-BSPUHZ-SW100VHA-BSPUHZ-SW100YHA-BSPUHZ-SW12
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
PUHZ-SW100VHAR4.UK PUHZ-SW120VHAR4.UK
PUHZ-SW100VHAR4-BS.UK PUHZ-SW120VHAR4-BS.UK
*1 *1
POWER SUPPLY
~/N 230V 50Hz
TO
INDOOR
UNIT
W
DCL
L
N S1 S2 S3
TB1
V
U
2
RD
WH
BK
MC
CN4
(WH)
3
1
RD
BU
YE
OG
BN
GNYE
BK
CNAC2
(RD)
CNAC1
(WH)
LINI
EI
E3
CN52C
(RD)
3
1
1
3
DCL1
DCL2
+
+
-
UVW
CNDC
(PK)
BK
2
MS
3~
E2
BK
E4
BK
CY1
CY2
IGBT
7
3
3
TH8
~
~
CN52C
(RD)
P. B.
BK WH
C. B.
TH6TH7 TH4TH3
21S4
LEV-A
CNS
(WH)
CNAC
(WH)
CNDC
(PK)
F2
F1
F3
F4
21S4
(GN)
CN2
(RD)
CN4
(WH)
TH7/6
(RD)
TH3
(WH)
TH4
(WH)
TRANS
CNM
(WH)
LED1
LED2
X52
SV1/CH
(GY)
X54
63H
(YE)
2
7
1 4 1 2 2 1
1 3
1
14
1 2
1 7
1
3
13
1 2
3 4
31 31
LEV-A
(WH)
51
SV3/SS
(WH)
X51
31
MF1
CNF1
(WH)
1
7
63L63H
63L
(RD)
1 3
31
TH34
2 1
TH34
(RD)
63HS
(WH)
63HS
LEV-B
(RD)
M
LEV-B
51
M
MF2
CNF2
(WH)
1
7
2
SW7
SW6SW1
SW9
SW5SW8SW4 SWP
31
CNDM
(WH)
MS
3~
MS
3~
1 2
CN2
(RD)
1 7
31
31
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
ON
100V
MODEL
SW6 SW5-6 *2
OFF
ON
OFF
ON
120V
OFF
ON
1 2 3 4 5 6
1 2 3 4 5 6
*1 MODEL SELECT
The black square (
) indicates a switch position.
*2 SW5 -1 to 5 : Function Switch
Thermistor <2-Phase Pipe>
TB1
MC
MF1, MF2
21S4
63H
63L
63HS
TH3
TH4
TH6
TH7
TH8
TH34
DCL
CY1, CY2
Terminal Block <Power
Supply, Indoor/Outdoor>
Motor for Compressor
Fan Motor
Solenoid Valve (4-Way Valve)
High Pressure Switch
Low Pressure Switch
High Pressure Sensor
Thermistor <Liquid>
Thermistor <Discharge>
Thermistor <Ambient>
Thermistor internal <Heat Sink>
Thermistor <Comp. Surface>
Linear Expansion Valve
Reactor
Capacitor
Power Circuit Board
P. B.
SYMBOL NAME SYMBOL NAME SYMBOL NAME
SW8
SW9
SWP
CNDM
SV1/CH
SV3/SS
CNM
F1, F2, F3, F4
Switch <Function Switch>
Switch <Function Switch>
Switch <Pump Down>
Connector <Connection for Option
>
Connector <Connection for Option
>
Connector <Connection for Option
>
Connector <Connection for Option
>
Fuse <T6.3AL250V>
LEV-A, LEV-B
Switch <Function Switch>
Switch <Function Switch, Model Select>
Switch <Model Select>
Switch <Function Switch>
SW4
SW1
Record Reset, Refrigerant Address
>
Controller Circuit Board
C. B.
SW5
SW6
SW7
Switch <Manual Defrost, Defect History
OCH533D