81
[Outdoor unit – Setting information] (Request code : "71")
Data display
Setting information 1
Setting information 2
00
Setting information 1
Display Defrost mode
0 Standard
1 For high humidity
Setting information 2
Display
Single-/ Heat pump/
3-phase
cooling only
0
Single-phase
Heat pump
1
Cooling only
2
3-phase
Heat pump
3
Cooling only
[Outdoor unit -– Capacity setting display] (Request code : "70")
Data display
Capacity
10 50
9 35
11 60
14 71
20 100
25 125
28 140
40 200
50 250