41
<M-NET communication error>
Note:“Indoorunit”inthetextindicatesM-NETboardinoutdoorunit.
Check code
Abnormal point and detection method
Case
Judgment and action
1–4 Checkpipe<liquidorcondenser/
evaporator>temperaturewithroom
temperaturedisplayonremote
controllerandoutdoorcontrollercircuit
board.
Pipe<liquidorcondenser/evaporator>
temperaturedisplayisindicatedby
settingSW2ofoutdoorcontrollercircuit
boardasfollows.
23Checkconverseconnectionofextension
pipeorconversewiringofindoor/outdoor
unitconnectingwire.
Conducttemperaturecheckwithoutdoor
controllercircuitboardafterconnecting
‘A-ControlServiceTool(PAC-SK52ST)’.
(
)
1 2 3 4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
1 2
3
4 5 6
ON
OFF
1 2 3 4 5 6
ON
OFF
A-Control Service Tool SW2 setting
Temperature display of indoor liquid pipe
Indoor 1
Temperature display of indoor liquid pipe
Indoor 2
Temperature display of indoor condenser/
evaporator pipe Indoor 1
Temperature display of indoor condenser/
evaporator pipe Indoor 2
P8
1Slighttemperaturedifference
betweenindoorroom
temperatureandpipe<liquid
orcondenser/evaporator>
temperaturethermistor
•Shortageofrefrigerant
•Disconnectedholderof
pipe<liquidorcondenser/
evaporator>thermistor
•Defectiverefrigerantcircuit
2Converseconnectionof
extensionpipe(onpluralunits
connection)
3Conversewiringofindoor/
outdoorunitconnectingwire(on
pluralunitsconnection)
4Defectivedetectionofindoor
roomtemperatureandpipe
<condenser/evaporator>
temperaturethermistor
5Stopvalveisnotopened
completely.
Pipe temperature
<Coolingmode>
Detectedasabnormalwhenthepipetem-
peratureisnotinthecoolingrange3min-
utesaftercompressorstartand6minutes
aftertheliquidorcondenser/evaporatorpipe
isoutofcoolingrange.
Note1:
Ittakesatleast9minutestodetect.
Note2:AbnormalityP8isnotdetectedin
dryingmode.
Coolingrange:Indoorpipetemperature
(TH2orTH5)−intaketemperature
(TH1)[−5.4˚F[−3:]
TH:Lowertemperaturebetweenliquidpipe
temperatureandcondenser/evaporator
temperature
<Heatingmode>
When10secondshavepassedafterthe
compressorstartsoperationandthehot
adjustmentmodehasfinished,theunitis
detectedasabnormalwhencondenser/
evaporatorpipetemperatureisnotinheat-
ingrangewithin20minutes.
Note3:Ittakesatleast27minutesto
detectabnormality.
Note4:Itexcludestheperiodofdefrosting
(Detectionrestartswhendefrosting
modeisover)
Heatingrange:
5.4˚F[3:]
[(Condenser/
evaporatortemperature(TH5)−
intaketemperature(TH1))
Check Code Abnormal point and detection method
Case Judgment and action
A0
(6600)
Address duplicate definition
Thiserrorisdisplayedwhentransmission
fromtheunitsofsameaddressisdetected.
Note:Theaddressandattributedisplayed
atremotecontrollerindicatethe
controllerthatdetectedabnormality.
1Thereare2ormoresame
addressofcontrollerofout-
doorunit,indoorunit,FRESH
MASTER,orLOSSNAY.
2Noisehasenteredintotrans-
missionsignalandsignalwas
transformed.
Searchtheunitwithsameaddressasabnormali-
tyoccurred.Ifthesameaddressisfound,turnoff
thepowersupplyofoutdoorunitandindoorunit
andFRESHMASTERorLOSSNAYatthesame
timefor2minutesormoreaftertheaddressis
corrected,andturnthepoweronagain.
Checktransmissionwaveformornoiseon
transmissionwire.
A2
(6602)
Hardware error of transmission processor
Transmissionprocessorintended
totransmit“0”,but“1”appearedon
transmissionwire.
Note:Theaddressandattributedisplay
atremotecontrollerindicatethe
controllerthatdetectedabnormality.
1
Errorisdetectedifwaveformis
transformedwhenwiringworksof
transmissionwireofoutdoorunit,
indoorunit,FRESHMASTERor
LOSSNAYaredone,orpolarityis
changedwiththepoweronand
transmissiondatacollideeachother.
2Defectivetransmittingreceiving
circuitoftransmissionprocessor
3Transmissiondataischangedby
thenoiseontransmission.
1Iftheworksoftransmissionwireisdone
withthepoweron,turnoffthepowersupply
ofoutdoorunitandindoorunitandFRESH
MASTERorLOSSNAYatthesametimefor
2minutesormore,andturnthepoweron
again.
2Checktransmissionwaveformornoiseon
transmissionwire.
A3
(6603)
BUS BUSY
1.Overtimeerrorbycollisiondamage
Abnormaliftransmittingsignalisnot
possiblefor8–10minutescontinuously
becauseofcollisionoftransmission.
2.Datacouldnotreachtransmissionwire
for8–10minutescontinuouslybecause
ofnoise,etc.
Note:Theaddressandattributedisplayed
atremotecontrollerindicatethecon-
trollerthatdetectedabnormality.
1
Transmissionprocessorcould
nottransmitsignalbecauseshort
cyclevoltageofnoiseandthe
likehaveenteredintotransmis-
sionwirecontinuously.
2Transmissionquantityhas
increasedandtransmissionis
notpossiblebecausetherewas
wiringmistakeofterminalblock
fortransmissionwire(TB3)and
terminalblockforcentralcontrol
(TB7)inoutdoorunit.
3Transmissionaremixedwith
othersandoccupationrateon
transmissionwirerosebecause
ofdefectiverepeater(afunction
toconnectorordisconnecttrans-
missionofcontrolandcentral
controlsystem)ofoutdoorunit,
thenabnormalityisdetected.
1Checkiftransmissionwireofindoorunit,
FRESHMASTER,LOSSNAY,orremotecon-
trollerisnotconnectedtoterminalblockfor
centralcontrol(TB7)ofoutdoorunit.
2Checkiftransmissionwireofindoorunit,
FRESHMASTERorLOSSNAYisnotcon-
nectedtoterminalblockfortransmissionwire
ofoutdoorunit.
3Checkifterminalblockfortransmissionwire
(TB3)andterminalblockforcentralcontrol
(TB7)arenotconnected.
4Checktransmissionwaveformornoiseon
transmissionwire.