4 - 27 4 - 27
4 SFC PROGRAM CONFIGURATION
MELSEC-Q
(4) Selection transition operation flowchart
St ep 2 Step 4 St ep 6
Step 1
Transition
condit ion “b
Transition
condit ion “e”
Transition
condit ion “h”
St ep 3 Step 5
Transition
condit ion “c
Transition
condit ion “f
Transition
condit ion “d”
Transition
condit ion “g
Transition
condit ion “i”
Step 7
Transition
condit ion “j
Initial step
Transition
condit ion “a”
Is transition condition
a satisfied?
Operation output of
initial step 0 is executed.
YES
YES
YES
YES
NO
Operation output of initial
step 0 is deactivated.
YESYES
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO
NO
Operation status
Operation output of initial
step 1 is executed.
Is transition condition
b satisfied?
Operation output of initial
step 1 is deactivated.
Operation output of initial
step 2 is executed.
Is transition condition
c satisfied?
Operation output of initial
step 2 is deactivated.
Operation output of initial
step 3 is executed.
Is transition condition
d satisfied?
Operation output of initial
step 3 is deactivated.
Operation output of initial
step 7 is executed.
Is transition condition
j satisfied?
Operation output of initial
step 7 is deactivated.
Block is ended since end
step is reached.
Is transition condition
e satisfied?
Operation output of initial
step 1 is deactivated.
Operation output of
initial step 4 is executed.
Is transition condition
f satisfied?
Operation output of initial
step 4 is deactivated.
Operation output of initial
step 5 is executed.
Is transition condition
g satisfied?
Operation output of initial
step 5 is deactivated.
Is transition condition
h satisfied?
Operation output of initial
step 1 is deactivated.
Operation output of initial
step 6 is executed.
Is transition condition
i satisfied?
Operation output of initial
step 6 is deactivated.

Table of Contents

Other manuals for Mitsubishi Q Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi Q Series and is the answer not in the manual?

Mitsubishi Q Series Specifications

General IconGeneral
I/O PointsUp to 4096 points
CommunicationEthernet, RS-232, RS-485
I/O ModulesDigital, Analog, Specialized
Programming LanguageFunction Block Diagram, Structured Text
Power Supply24V DC, 100-240V AC
Operating Temperature0°C to 55°C
Shock Resistance147 m/s2 acceleration, 3 times in each of X, Y, and Z directions
Program CapacityUp to 252K steps